EMC, LVD and RoHS test reports and conformity certificates.
54 dated test and conformity records from 2017–2026, listed by product family and model, plus the factory-supplied ISO 9001 certificate image and DONTA trademark records. Redacted page previews appear where the register shows one.
Documents held, by product family.
EMC and LVD reports with their conformity certificates, and RoHS reports on selected materials or components, for the TR, CF and TL solar street lights, the SG solar garden lights and the BW solar floodlights; EMC and LVD for the LY street lights; FCC Part 15B for BW.
Product family
Models named
Documents held
Dated
TR solar street lights
TR408-C and named TR variants
EMC report and conformity certificate; LVD report and voluntary conformity assessment certificate; RoHS selected-material report and certificate (6 records)
2025
CF solar street lights
CF3078, CF2040-15W, CF3055-30W
EMC report and conformity certificate; LVD report and conformity certificate; RoHS selected-material report and certificate (6 records)
2026
TL solar street lights
TL41145 and TL35125-100W
EMC report and conformity certificate; LVD report and conformity certificate; RoHS selected-material report and certificate (6 records)
2026
LY solar street lights
LY-C (tested) and six related models; the EMC certificate names only the six
EMC report and conformity certificate; LVD report and conformity certificate (4 records)
2026
SG solar garden lights
SG-1 through SG-12
EMC report and conformity certificate; LVD report and voluntary conformity assessment certificate; RoHS selected-component report and certificate (6 records)
2024
BW solar floodlights
BW-C3 and eight related BW variants
EMC, LVD and RoHS reports and conformity certificates or attestations; FCC Part 15B report and attestation (8 records)
2025–2026
M2 LED floodlights
M2-50W, M2-100W and M2-150W
EMC and luminaire-safety reports with declarations, listed by metadata only; PSE is not currently maintained (factory statement, 29 September 2026; 4 records)
2026
Earlier M2, ML6 and ML7 records
M2, ML6 and ML7 identifiers
EMC, LVD and RoHS reports, certificates and declarations, listed by historical metadata only (14 records)
2017–2018
Each record covers only the models it names. Tested, listed and series models stay distinct: a listing does not mean the model was separately tested. The register below lists every one with its number, issuer, date and scope.
ISO 9001 certificate and DONTA trademark.
Web copies of our ISO 9001 certificate and DONTA trademark records, made from factory-supplied images. QR codes, handwritten signatures and the issuer’s contact lines are masked.
ISO 9001 quality management certificate
Certificate 04926Q00260R301 names Zhongshan Xiuben Lighting Co., Ltd. and prints a 2026-04-13 to 2029-04-09 period for an outdoor-light research, manufacture and export-sales-service scope.
Factory-provided image, not independently registry-verified: the issuer’s certificate search requires a CAPTCHA.
The supplied China trademark certificate names Xiuben as registrant of DONTA, registration 11772641, in Class 11.
The address printed on this older record is historical, not the current contact address. TÜV Rheinland supplier verification report 487829483_P+T records an owned trademark count of zero for this legal entity; that record and this certificate have not been reconciled, and its current registry status has not been independently confirmed.
DONTA renewal
The supplied renewal record carries the same registration number and shows a renewed term through 2034-04-27.
A China document summary. For a current registry, territory or legal-rights decision, obtain the official registry record or legal advice.
TÜV Rheinland supplier verification.
Xiuben Lighting’s authorized marketplace profile displays “Verified Supplier” with “Manufacturer” capability, attributing the assessment to TÜV Rheinland. Use it as a supplier-profile indicator only. The figures recorded in the on-site verification report are on our company page.
Each row gives the document number, type, issuer, date and the models it names. The applicant and manufacturer fields name Zhongshan Xiuben Lighting Co., Ltd. Forty-two redacted page previews cover the earlier 36-record set. The four M2 records and fourteen historical rows are metadata-only: no report page, result extract or original PDF is published. Verify any record by its number with the issuing laboratory.
No public records match this exact model identifier or document-number search. Check the identifier and the stated scope, or ask which current documents are available for your model.
On a small screen, swipe each table sideways to see every column.
Solar garden lights6 records · SG-1 through SG-12 · 2024
Record
Type
Named scope
Date / result / limit
AOCE2411181505-EC EMC conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of EMC conformity certificate / attestation AOCE2411181505-EC, dated 2024-11-22; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Conformity certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN 61547:2009
Referenced report: AOCE2411181505-E
Solar Garden Light Named models: SG-12, SG-1, SG-2, SG-3, SG-4, SG-5, SG-6, SG-7, SG-8, SG-9, SG-10, SG-11
2024-11-22 Document metadata and named-model scope only; do not describe this as universal product certification.
AOCE2411181505-SC LVD voluntary conformity assessment certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of LVD voluntary conformity assessment certificate / attestation AOCE2411181505-SC, dated 2024-11-22; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Voluntary conformity assessment certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 60598-2-1:2021
EN IEC 60598-1:2021+A11:2022
Referenced report: AOCE2411181505-S
Solar Garden Light Named models: SG-12, SG-1, SG-2, SG-3, SG-4, SG-5, SG-6, SG-7, SG-8, SG-9, SG-10, SG-11
2024-11-22 Voluntary sample and technical-file assessment; do not describe this as universal product certification.
AOCE2411181505-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 27 of EMC test report AOCE2411181505-E, dated 2024-11-22; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN 61547:2009
Solar Garden Light Tested model: SG-12; related listed models: SG-1, SG-2, SG-3, SG-4, SG-5, SG-6, SG-7, SG-8, SG-9, SG-10, SG-11
2024-11-22 Pass recorded for the tested sample Tested-sample scope only; do not extend the result to every listed model, configuration or production unit without confirmation.
AOCE2411181505-S LVD test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 57 of LVD test report AOCE2411181505-S, dated 2024-11-22; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Test reportStandards and report reference
References named in this document:
EN IEC 60598-2-1:2021
EN IEC 60598-1:2021+A11:2022
EN 62031:2008+A1:2013+A2:2015
Solar Garden Light Tested model: SG-12; related listed models: SG-1, SG-2, SG-3, SG-4, SG-5, SG-6, SG-7, SG-8, SG-9, SG-10, SG-11
2024-11-22 Test-report and tested-sample scope only. No ingress-protection value is published because the report contains conflicting references.
KEYS241120017001RH-03 RoHS Certificate of Conformity Guangdong KEYS Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of RoHS Certificate of Conformity KEYS241120017001RH-03, dated 2024-11-27; source: Guangdong KEYS Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Certificate of Conformity tied to a test reportStandards and report reference
Referenced report: KEYS241120017001RH-03
Solar Garden Light Named models: SG-12, SG-1, SG-2, SG-3, SG-4, SG-5, SG-6, SG-7, SG-8, SG-9, SG-10, SG-11
2024-11-27 The document says it applies to the tested sample only and does not imply assessment of the whole production.
KEYS241120017001RH-03 RoHS selected-component test report Guangdong KEYS Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 15 of RoHS selected-component test report KEYS241120017001RH-03, dated 2024-11-27; source: Guangdong KEYS Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Test report
Solar Garden Light Named models: SG-12, SG-1, SG-2, SG-3, SG-4, SG-5, SG-6, SG-7, SG-8, SG-9, SG-10, SG-11
2024-11-27 Pass recorded for the requested tests on the submitted sample components Submitted-sample and selected-component scope only; the report says unlisted components were not tested and does not establish whole-production conformity.
TR solar street lights6 records · TR408-C and named TR variants · 2025
These records name TR408-C and the hyphenated variants listed below. A similar catalogue name is not a document match, so match the exact model and supplied configuration for your order.
Record
Type
Named scope
Date / result / limit
AOCE250627899-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 26 of EMC test report AOCE250627899-E, dated 2025-07-01; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN 61547:2009
LED Solar Street Light Tested model: TR408-C; related listed models: TR248-A, TR248-B, TR248-C, TR300-A, TR300-B, TR300-C, TR348-A, TR348-B, TR348-C, TR408-A, TR408-B
2025-07-01 Pass recorded for the tested sample Tested-sample scope only. Listed models are not represented as separately tested; confirm the exact order configuration and current applicability.
AOCE250627899-EC EMC conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of EMC conformity certificate / attestation AOCE250627899-EC, dated 2025-07-01; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Conformity certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN 61547:2009
Referenced report: AOCE250627899-E
LED Solar Street Light Named models: TR408-C, TR248-A, TR248-B, TR248-C, TR300-A, TR300-B, TR300-C, TR348-A, TR348-B, TR348-C, TR408-A, TR408-B
2025-07-01 Sample-evaluation conclusion stated Factory-provided sample-evaluation attestation referencing AOCE250627899-E. Its named-model list does not show separate tests of every model.
AOCE250627899-S CE-LVD road/street-light test report Zhongshan AOCE Testing Technology Co., Ltd.View 2 redacted page imagesRedacted web copy of page 1 of 40 of CE-LVD road/street-light test report AOCE250627899-S, dated 2025-07-01; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Page 4 of this report shows the limitation that applies to this result. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.Redacted web copy of page 4 of 40 of CE-LVD road/street-light test report AOCE250627899-S, dated 2025-07-01; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. This page records that the products were considered to comply with EN 62493:2015 without testing under clause 4.2.2, and lists the variants the report names.
Test reportStandards and report reference
References named in this document:
EN 60598-2-3:2003+A1:2011
EN IEC 60598-1:2021+A11:2022
EN 62493:2015 — considered satisfied without testing under clause 4.2.2
IEC 62031:2018 and EN IEC 62031:2020 — LED-module requirements in Attachment 1
LED Solar Street Light Tested model: TR408-C; related listed models: TR248-A, TR248-B, TR248-C, TR300-A, TR300-B, TR300-C, TR348-A, TR348-B, TR348-C, TR408-A, TR408-B
2025-07-01 TR408-C identified as the tested sample; see assessment limits TR408-C is the sample stated as fully tested; listed variants are not separately tested. The report considers EN 62493:2015 satisfied without testing under clause 4.2.2. No broader configuration or production conformity follows.
AOCE250627899-SC LVD conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of LVD conformity certificate / attestation AOCE250627899-SC, dated 2025-07-01; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Voluntary conformity assessment certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN 60598-2-3:2003+A1:2011
EN IEC 60598-1:2021+A11:2022
Referenced report: AOCE250627899-S
LED Solar Street Light Named models: TR408-C, TR248-A, TR248-B, TR248-C, TR300-A, TR300-B, TR300-C, TR348-A, TR348-B, TR348-C, TR408-A, TR408-B
2025-07-01 Sample-evaluation conclusion stated Voluntary assessment of a sample and technical file, referencing AOCE250627899-S. This is not the manufacturer/importer declaration required before CE marking; confirm current requirements and the exact supplied configuration.
AZT250702002C-E0 RoHS selected-material test report Shenzhen AZT Technology Co., Ltd.View 2 redacted page imagesRedacted web copy of page 1 of 17 of RoHS selected-material test report AZT250702002C-E0, dated 2025-07-08; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Page 11 of this report shows the limitation that applies to this result. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.Redacted web copy of page 11 of 17 of RoHS selected-material test report AZT250702002C-E0, dated 2025-07-08; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. This page shows the lead results and the copper-alloy exemption the report relies on; the exemption and its current applicability are not independently assessed here.
Test reportStandards and report reference
References named in this document:
RoHS Directive 2011/65/EU Annex II amended by Directive (EU) 2015/863
IEC 62321-3-1:2013
IEC 62321-5:2013
IEC 62321-4:2013+AMD1:2017 CSV
IEC 62321-6:2015
IEC 62321-7-1:2015
IEC 62321-7-2:2017
IEC 62321-8:2017
LED Solar Street Light Tested model: TR408-C; named series models: TR248-A, TR248-B, TR248-C, TR300-A, TR300-B, TR300-C, TR348-A, TR348-B, TR348-C, TR408-A, TR408-B
2025-07-08 Pass recorded; see report dependency Submitted-sample and selected-material scope only. Parts 36/37 record lead at 17,748/28,372 mg/kg against a printed 1,000 mg/kg limit; the report invokes the copper-alloy exemption in Annex III 6(c). That exemption and its current applicability are not independently assessed here.
AZT250702002C-EV0 RoHS Certificate of Conformity Shenzhen AZT Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of RoHS Certificate of Conformity AZT250702002C-EV0, dated 2025-07-08; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Certificate of Conformity tied to a test reportStandards and report reference
References named in this document:
RoHS Directive 2011/65/EU Annex II amended by Directive (EU) 2015/863
IEC 62321-3-1:2013
IEC 62321-5:2013
IEC 62321-4:2013+AMD1:2017 CSV
IEC 62321-6:2015
IEC 62321-7-1:2015
IEC 62321-7-2:2017
IEC 62321-8:2017
Referenced report: AZT250702002C-E0
LED Solar Street Light Tested model: TR408-C; named series models: TR248-A, TR248-B, TR248-C, TR300-A, TR300-B, TR300-C, TR348-A, TR348-B, TR348-C, TR408-A, TR408-B
2025-07-08 Submitted-sample conclusion stated Selected-material and submitted-sample scope only; read with AZT250702002C-E0. Its conclusion depends on the report’s high-lead copper-alloy results and stated exemption, not independently assessed here.
CF solar street lights6 records · CF3078, CF2040-15W, CF3055-30W · 2026
Record
Type
Named scope
Date / result / limit
AOCE260416593-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 26 of EMC test report AOCE260416593-E, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration.
Test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN IEC 61547:2023
Solar Street Light Tested model: CF3078; related listed models: CF2040-15W, CF3055-30W
2026-04-20 Pass recorded for the tested sample Tested-sample and named-model document scope only; listed models are not represented as separately tested, current, available, or production-conforming.
AOCE260416593-EC EMC conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of EMC conformity certificate / attestation AOCE260416593-EC, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose.
Conformity certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN IEC 61547:2023
Referenced report: AOCE260416593-E
Solar Street Light Named models: CF3078, CF2040-15W, CF3055-30W
2026-04-20 Sample-evaluation conclusion stated Document metadata and evaluated/tested-sample scope only; not universal certification, current validity, authenticity, accreditation or market applicability.
AOCE260416593-S CE-LVD road/street-light test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 40 of CE-LVD road/street-light test report AOCE260416593-S, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The EN IEC 60598-1 editions printed on this report and its certificate differ; no edition is normalised here.
Test report
Solar Street Light Tested model: CF3078; related listed models: CF2040-15W, CF3055-30W
2026-04-20 Full test stated for CF3078 Tested-sample report scope only; only CF3078 is expressly full-tested. No normalized standard edition is published, and the result is not extended to listed models or production.
AOCE260416593-SC LVD conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of LVD conformity certificate / attestation AOCE260416593-SC, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The EN IEC 60598-1 editions printed on this report and its certificate differ; no edition is normalised here.
Conformity certificate / attestation referencing a test reportStandards and report reference
Referenced report: AOCE260416593-S
Solar Street Light Named models: CF3078, CF2040-15W, CF3055-30W
2026-04-20 Sample-evaluation conclusion stated Evaluated/tested-sample document scope only; no governing standard edition is inferred and this is not described as universal certification.
AZT260421065C-E0 RoHS selected-material test report Shenzhen AZT Technology Co., Ltd.View 2 redacted page imagesRedacted web copy of page 1 of 17 of RoHS selected-material test report AZT260421065C-E0, dated 2026-05-13; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Page 11 of this report shows the limitation that applies to this result.Redacted web copy of page 11 of 17 of RoHS selected-material test report AZT260421065C-E0, dated 2026-05-13; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. This page shows the lead result and the copper-alloy exemption the report relies on; the exemption and its current applicability are not independently assessed here.
Test report
Solar Street Light Tested model: CF3078; named series models: CF2040-15W, CF3055-30W
2026-05-13 Pass recorded; see report dependency Submitted-sample and selected-material scope only. The report records lead at 23,917 mg/kg for part 26 against its printed 1,000 mg/kg limit and itself invokes a copper-alloy exemption; this site does not assess that exemption or infer broader conformity.
AZT260421065C-EV0 RoHS Certificate of Conformity Shenzhen AZT Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of RoHS Certificate of Conformity AZT260421065C-EV0, dated 2026-05-13; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose.
Certificate of Conformity tied to a test reportStandards and report reference
Referenced report: AZT260421065C-E0
Solar Street Light Tested model: CF3078; named series models: CF2040-15W, CF3055-30W
2026-05-13 Submitted-sample conclusion stated Submitted-sample/selected-material certificate scope only. Its referenced report records lead at 23,917 mg/kg for part 26 against its printed 1,000 mg/kg limit and itself invokes a copper-alloy exemption; no broader conformity is inferred.
TL solar street lights6 records · TL41145 and TL35125-100W · 2026
Record
Type
Named scope
Date / result / limit
AOCE260416592-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 26 of EMC test report AOCE260416592-E, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration.
Test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN IEC 61547:2023
Solar Street Light Tested model: TL41145; related listed models: TL35125-100W
2026-04-20 Pass recorded for the tested sample Tested-sample and named-model document scope only; the listed model is not represented as separately tested, current, available, or production-conforming.
AOCE260416592-EC EMC conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of EMC conformity certificate / attestation AOCE260416592-EC, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose.
Conformity certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN IEC 61547:2023
Referenced report: AOCE260416592-E
Solar Street Light Named models: TL41145, TL35125-100W
2026-04-20 Sample-evaluation conclusion stated Document metadata and evaluated/tested-sample scope only; not universal certification, current validity, authenticity, accreditation or market applicability.
AOCE260416592-S CE-LVD road/street-light test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 40 of CE-LVD road/street-light test report AOCE260416592-S, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The EN IEC 60598-1 editions printed on this report and its certificate differ; no edition is normalised here.
Test report
Solar Street Light Tested model: TL41145; related listed models: TL35125-100W
2026-04-20 Full test stated for TL41145 Tested-sample report scope only; only TL41145 is expressly full-tested. No normalized standard edition is published, and the result is not extended to the listed model or production.
AOCE260416592-SC LVD conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of LVD conformity certificate / attestation AOCE260416592-SC, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The EN IEC 60598-1 editions printed on this report and its certificate differ; no edition is normalised here.
Conformity certificate / attestation referencing a test reportStandards and report reference
Referenced report: AOCE260416592-S
Solar Street Light Named models: TL41145, TL35125-100W
2026-04-20 Sample-evaluation conclusion stated Evaluated/tested-sample document scope only; no governing standard edition is inferred and this is not described as universal certification.
AZT260421063C-E0 RoHS selected-material test report Shenzhen AZT Technology Co., Ltd.View 2 redacted page imagesRedacted web copy of page 1 of 22 of RoHS selected-material test report AZT260421063C-E0, dated 2026-05-18; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Page 15 of this report shows the limitation that applies to this result.Redacted web copy of page 15 of 22 of RoHS selected-material test report AZT260421063C-E0, dated 2026-05-18; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. This page shows the lead results and the copper-alloy exemption the report relies on; the exemption and its current applicability are not independently assessed here.
Test report
Solar Street Light Tested model: TL41145; named series models: TL35125-100W
2026-05-18 Pass recorded; see report dependency Submitted-sample and selected-material scope only. The report records lead at 22,958 and 21,873 mg/kg for parts 33 and 43 against its printed 1,000 mg/kg limit and itself invokes a copper-alloy exemption; this site does not assess that exemption or infer broader conformity.
AZT260421063C-EV0 RoHS Certificate of Conformity Shenzhen AZT Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of RoHS Certificate of Conformity AZT260421063C-EV0, dated 2026-05-18; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose.
Certificate of Conformity tied to a test reportStandards and report reference
Referenced report: AZT260421063C-E0
Solar Street Light Tested model: TL41145; named series models: TL35125-100W
2026-05-18 Submitted-sample conclusion stated Submitted-sample/selected-material certificate scope only. Its referenced report records lead at 22,958 and 21,873 mg/kg for parts 33 and 43 against its printed 1,000 mg/kg limit and itself invokes a copper-alloy exemption; no broader conformity is inferred.
LY solar street lights4 public records · LY-C and six related models · 2026
The associated EMC report tests LY-C, while the certificate itself names only six related models. The register keeps each document’s own model list and does not use one file to expand another.
Record
Type
Named scope
Date / result / limit
AOCE260416594-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 26 of EMC test report AOCE260416594-E, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration.
Test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN IEC 61547:2023
Solar Street Light Tested model: LY-C; related listed models: LY-D, LY-B, LY-A, LY30-C, LY30-B, LY30-A
2026-04-20 Pass recorded for the tested sample Tested-sample and named-model document scope only; the report is not used to add LY-C to the linked certificate's printed model list.
AOCE260416594-EC EMC conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of EMC conformity certificate / attestation AOCE260416594-EC, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose.
Conformity certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN IEC 61547:2023
Referenced report: AOCE260416594-E
Solar Street Light Named models: LY-D, LY-B, LY-A, LY30-C, LY30-B, LY30-A
2026-04-20 Sample-evaluation conclusion stated Exact printed certificate-model scope only; this certificate is not mapped to LY-C and no current validity, authenticity, accreditation, market applicability, availability or production conformity is inferred.
AOCE260416594-S CE-LVD road/street-light test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 40 of CE-LVD road/street-light test report AOCE260416594-S, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The EN IEC 60598-1 editions printed on this report and its certificate differ; no edition is normalised here.
Test report
Solar Street Light Tested model: LY-C; related listed models: LY-D, LY-B, LY-A, LY30-C, LY30-B, LY30-A
2026-04-20 Full test stated for LY-C Tested-sample report scope only; only LY-C is expressly full-tested. No normalized standard edition is published, and the result is not extended to listed models or production.
AOCE260416594-SC LVD conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of LVD conformity certificate / attestation AOCE260416594-SC, dated 2026-04-20; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The EN IEC 60598-1 editions printed on this report and its certificate differ; no edition is normalised here.
Conformity certificate / attestation referencing a test reportStandards and report reference
Referenced report: AOCE260416594-S
Solar Street Light Named models: LY-C, LY-D, LY-B, LY-A, LY30-C, LY30-B, LY30-A
2026-04-20 Sample-evaluation conclusion stated Evaluated/tested-sample document scope only; no governing standard edition is inferred and this is not described as universal certification.
BW solar floodlights8 records · BW-C3 and eight related BW variants · 2025–2026
Match the exact numbered configuration to each record. Related-model listings do not mean every model was separately tested. The electrical-rating clarification and selected-material limitations are in the rows below.
Record
Type
Named scope
Date / result / limit
AOCE250614815-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 26 of EMC test report AOCE250614815-E, dated 2025-06-18; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN 61547:2009
LED Solar Light Tested model: BW-C3; related listed models: BW-A1, BW-A2, BW-A3, BW-B1, BW-B2, BW-B3, BW-C1, BW-C2
2025-06-18 Pass recorded for tested sample Factory-provided tested-sample report. BW-C3 is the stated tested model; the eight listed models are not represented as separately tested. Confirm the exact order configuration and current applicability.
AOCE250614815-EC EMC conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of EMC conformity certificate / attestation AOCE250614815-EC, dated 2025-06-18; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Conformity certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN IEC 55015:2019+A11:2020
EN 61547:2009
Referenced report: AOCE250614815-E
LED Solar Light Named models: BW-C3, BW-A1, BW-A2, BW-A3, BW-B1, BW-B2, BW-B3, BW-C1, BW-C2
2025-06-18 Sample-evaluation conclusion stated Factory-provided sample-evaluation attestation referencing AOCE250614815-E. Named models are not represented as separately tested.
AOCE250614815-S CE-LVD test report Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 49 of CE-LVD test report AOCE250614815-S, dated 2025-06-18; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Test reportStandards and report reference
References named in this document:
EN 60598-2-5:2015
EN IEC 60598-1:2021+A11:2022
EN 61347-1:2015+A1:2021
EN 61347-2-11:2001+A1:2010
EN IEC 62031:2020+A11:2021
IEC 62471:2006 (client-declared LED application)
LED Solar Light Tested model: BW-C3; related listed models: BW-A1, BW-A2, BW-A3, BW-B1, BW-B2, BW-B3, BW-C1, BW-C2
2025-06-18 BW-C3 is the representative tested sample; related models are not represented as individually tested. The report contains inconsistent electrical ratings. Obtain laboratory clarification of the electrical configuration before relying on it for an order.
AOCE250614815-SC LVD conformity certificate / attestation Zhongshan AOCE Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of LVD conformity certificate / attestation AOCE250614815-SC, dated 2025-06-18; source: Zhongshan AOCE Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Voluntary conformity assessment certificate / attestation referencing a test reportStandards and report reference
References named in this document:
EN 60598-2-5:2015
EN IEC 60598-1:2021
Referenced report: AOCE250614815-S
LED Solar Light Named models: BW-C3, BW-A1, BW-A2, BW-A3, BW-B1, BW-B2, BW-B3, BW-C1, BW-C2
2025-06-18 Voluntary sample-assessment conclusion stated Voluntary sample assessment referencing AOCE250614815-S; named models are not represented as separately tested. Clarify the linked report's electrical configuration before order reliance. This attestation lists EN IEC 60598-1:2021; the report includes A11:2022. Confirm the applicable edition with the laboratory.
AZT250616011C-E0 RoHS selected-material test report Shenzhen AZT Technology Co., Ltd.View 2 redacted page imagesRedacted web copy of page 1 of 15 of RoHS selected-material test report AZT250616011C-E0, dated 2025-06-20; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Page 10 of this report shows the limitation that applies to this result. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.Redacted web copy of page 10 of 15 of RoHS selected-material test report AZT250616011C-E0, dated 2025-06-20; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. This page shows the result table and the copper-alloy exemption the report relies on; the exemption and its current applicability are not independently assessed here.
Test reportStandards and report reference
References named in this document:
RoHS Directive 2011/65/EU Annex II amended by Directive (EU) 2015/863
IEC 62321-3-1:2013
IEC 62321-5:2013
IEC 62321-4:2013+AMD1:2017 CSV
IEC 62321-6:2015
IEC 62321-7-1:2015
IEC 62321-7-2:2017
IEC 62321-8:2017
Solar Flood Light Tested model: BW-C3; named series models: BW-A1, BW-A2, BW-A3, BW-B1, BW-B2, BW-B3, BW-C1, BW-C2
2025-06-20 Pass recorded; see report dependency Submitted-sample and selected-material scope only; related models are not represented as individually tested. The report's Pass conclusion uses its stated copper-alloy exemption. That exemption and its current applicability are not independently assessed here.
AZT250616011C-EV0 RoHS Certificate of Conformity Shenzhen AZT Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of RoHS Certificate of Conformity AZT250616011C-EV0, dated 2025-06-20; source: Shenzhen AZT Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. The No. 17 Qinglong Road address printed on this record is historical document context, not the current contact address.
Certificate of Conformity tied to a test reportStandards and report reference
References named in this document:
RoHS Directive 2011/65/EU Annex II amended by Directive (EU) 2015/863
IEC 62321-3-1:2013
IEC 62321-5:2013
IEC 62321-4:2013+AMD1:2017 CSV
IEC 62321-6:2015
IEC 62321-7-1:2015
IEC 62321-7-2:2017
IEC 62321-8:2017
Referenced report: AZT250616011C-E0
Solar Flood Light Tested model: BW-C3; named series models: BW-A1, BW-A2, BW-A3, BW-B1, BW-B2, BW-B3, BW-C1, BW-C2
2025-06-20 Submitted-sample conclusion stated Selected-material and submitted-sample scope only; related models are not represented as individually tested. Read with AZT250616011C-E0: its conclusion uses the report's stated copper-alloy exemption, not independently assessed here.
26AE050961F001 FCC Part 15B attestation of conformity Guangdong Global Testing Technology Co., Ltd.View redacted page imageRedacted web copy of page 1 of 1 of FCC Part 15B attestation of conformity 26AE050961F001, dated 2026-05-29; source: Guangdong Global Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Ratings printed on this page, including any ingress-protection code, describe the submitted sample as the laboratory recorded it, not a current or offered configuration.
Attestation of Conformity (not an FCC-issued certificate)Standards and report reference
References named in this document:
FCC 47 CFR Part 15 Subpart B
Referenced report: E04A26050961F00101
Solar Flood Light Named models: BW-A1, BW-B1, BW-C1, BW-A2, BW-B2, BW-C2, BW-C3, BW-A3, BW-B3
2026-05-29 Factory-provided product-sample attestation referencing E04A26050961F00101. Named models are not represented as separately tested; this is not an FCC-issued certificate.
E04A26050961F00101 FCC Part 15B test report Guangdong Global Testing Technology Co., Ltd.View 2 redacted page imagesRedacted web copy of page 1 of 26 of FCC Part 15B test report E04A26050961F00101, dated 2026-05-29; source: Guangdong Global Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. Page 3 of this report shows the limitation that applies to this result.Redacted web copy of page 3 of 26 of FCC Part 15B test report E04A26050961F00101, dated 2026-05-29; source: Guangdong Global Testing Technology Co., Ltd. Laboratory contact details, QR codes and handwritten signatures are masked; ask which complete file, if any, can be supplied for the exact model and purpose. This page records radiated emissions above 1 GHz as N/A, not passed.
FCC Part 15B test reportStandards and report reference
References named in this document:
FCC 47 CFR Part 15 Subpart B
Solar Flood Light Tested model: BW-C3; named series models: BW-A1, BW-B1, BW-C1, BW-A2, BW-B2, BW-C2, BW-A3, BW-B3
2026-05-29 Conducted emissions and radiated emissions below 1 GHz: Pass recorded for tested sample; radiated above 1 GHz: N/A Factory-provided tested-sample report. BW-C3 is the stated tested model; the eight listed models are not represented as separately tested. Above-1 GHz radiated testing is printed N/A, not passed.
M2 LED floodlights, dated metadata4 records · M2-50W, M2-100W and M2-150W · 2026
These rows identify documents dated 26 May 2026. The report metadata identifies M2-150W as the tested model and lists M2-50W and M2-100W; the declarations name the three models. No page preview or result extract is published. The factory stated on 29 September 2026 that PSE is not currently maintained. The rows show no current validity, approval, marking entitlement, match to an ordered configuration or laboratory consent for commercial reproduction.
Record
Type
Named scope
Date / scope / limit
AOCE260521803-E EMC test report Zhongshan AOCE Testing Technology Co., Ltd.
EMC test reportStandards and report reference
References named in this document:
J55015 (H29)
LED Flood Light Tested model: M2-150W; related listed models: M2-50W, M2-100W
2026-05-26 M2-150W is identified as the tested sample; M2-50W and M2-100W are listed, not separately identified as tested. Dated, factory-provided metadata only. The factory stated on 29 September 2026 that PSE is not currently maintained. Current validity, ordered-configuration applicability, approval, marking entitlement and laboratory consent for commercial reproduction are not established.
Declaration of Conformity — EMCStandards and report reference
References named in this document:
J55015 (H29)
Referenced report: AOCE260521803-E
LED Flood Light Named models: M2-150W, M2-50W, M2-100W
2026-05-26 Named-model voluntary assessment metadata only; no individual tested-model field appears on this declaration. The printed PSE-mark conditions remain manufacturer/importer responsibilities. The factory stated on 29 September 2026 that PSE is not currently maintained. Current validity, ordered-configuration applicability, approval, marking entitlement and laboratory consent for commercial reproduction are not established.
Luminaire safety test reportStandards and report reference
References named in this document:
J60598-2-5(H29)
J60598-1(H29)
LED Flood Light Tested model: M2-150W; related listed models: M2-50W, M2-100W
2026-05-26 M2-150W is identified as the tested model; M2-50W and M2-100W are listed. National-difference coverage is printed N/A. Dated, factory-provided metadata only. The factory stated on 29 September 2026 that PSE is not currently maintained. Current validity, ordered-configuration applicability, approval, marking entitlement and laboratory consent for commercial reproduction are not established.
Declaration of Conformity — safety referencesStandards and report reference
References named in this document:
J60598-2-5(H29)
J60598-1(H29)
Referenced report: AOCE260521803-S
LED Flood Light Named models: M2-150W, M2-50W, M2-100W
2026-05-26 Named-model declaration metadata only. The requirements line following ‘Complies with the requirements of the’ is blank in the supplied face; no missing legal requirement is inferred. The factory stated on 29 September 2026 that PSE is not currently maintained. Current validity, ordered-configuration applicability, approval, marking entitlement and laboratory consent for commercial reproduction are not established.
Earlier records, historical metadata14 records · M2, ML6 and ML7 identifiers · 2017–2018
These rows keep the literal document numbers, dates, issuers and named or tested-model roles from earlier factory-supplied documents, as unverified historical metadata. They show no current approval, current offered configuration or marking entitlement, and no page image, source file or test result is published.
2017-12-21 Historical metadata from a factory-supplied 2017 document. The printed identifier list includes ‘ML2-180W’. It is retained exactly and is not normalized to ‘M2-180W’. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2017-12-21 Historical metadata from a factory-supplied 2017 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2017-12-20 Historical metadata from a factory-supplied 2017 document. The printed identifier list includes ‘ML2-180W’. It is retained exactly and is not normalized to ‘M2-180W’. The testing category is not established by the checked metadata. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2017-12-20 Historical metadata from a factory-supplied 2017 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-05 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-14 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-14 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-13 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-13 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-05 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-14 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-14 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-13 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
2018-09-13 Historical metadata from a factory-supplied 2018 document. This row does not establish current validity, a current offered configuration, approval, or marking entitlement. The source file remains private.
Which documents name your model?
Match the exact identifier, recorded sample and stated limitation before relying on a record. A matching record does not establish the current configuration.
CF2040 No exact-name match
Document scope: CF2040
Match the quoted configuration to the named models, sample and scope before relying on a document.
Current configuration match: not established.
No exact-name match is not a conclusion about testing or documents that may be available for an enquiry.
Standards as recorded: EN IEC 55015:2019+A11:2020; EN IEC 61547:2023
Recorded conclusion: Pass recorded for the tested sample
Tested-sample and named-model document scope only; listed models are not represented as separately tested, current, available, or production-conforming.
Request a current file match before relying on this record.
/quality-documents/#document-aoce260416593-e
AOCE260416593-EC — Conformity certificate / attestation referencing a test report; 2026-04-20; Zhongshan AOCE Testing Technology Co., Ltd.
Subject: Solar Street Light
Named models: CF3078, CF2040-15W, CF3055-30W
Referenced report: AOCE260416593-E
Standards as recorded: EN IEC 55015:2019+A11:2020; EN IEC 61547:2023
Recorded conclusion: Sample-evaluation conclusion stated
Document metadata and evaluated/tested-sample scope only; not universal certification, current validity, authenticity, accreditation or market applicability.
Request a current file match before relying on this record.
Tested-sample report scope only; only CF3078 is expressly full-tested. No normalized standard edition is published, and the result is not extended to listed models or production.
Request a current file match before relying on this record.
/quality-documents/#document-aoce260416593-s
AOCE260416593-SC — Conformity certificate / attestation referencing a test report; 2026-04-20; Zhongshan AOCE Testing Technology Co., Ltd.
Subject: Solar Street Light
Named models: CF3078, CF2040-15W, CF3055-30W
Referenced report: AOCE260416593-S
Recorded conclusion: Sample-evaluation conclusion stated
Evaluated/tested-sample document scope only; no governing standard edition is inferred and this is not described as universal certification.
Request a current file match before relying on this record.
/quality-documents/#document-aoce260416593-sc
AZT260421065C-E0 — Test report; 2026-05-13; Shenzhen AZT Technology Co., Ltd.
Subject: Solar Street Light
Tested model: CF3078
Series models: CF2040-15W, CF3055-30W
Recorded conclusion: Pass recorded; see report dependency
Submitted-sample and selected-material scope only. The report records lead at 23,917 mg/kg for part 26 against its printed 1,000 mg/kg limit and itself invokes a copper-alloy exemption; this site does not assess that exemption or infer broader conformity.
Request a current file match before relying on this record.
/quality-documents/#document-azt260421065c-e0
AZT260421065C-EV0 — Certificate of Conformity tied to a test report; 2026-05-13; Shenzhen AZT Technology Co., Ltd.
Subject: Solar Street Light
Tested model: CF3078
Series models: CF2040-15W, CF3055-30W
Referenced report: AZT260421065C-E0
Recorded conclusion: Submitted-sample conclusion stated
Submitted-sample/selected-material certificate scope only. Its referenced report records lead at 23,917 mg/kg for part 26 against its printed 1,000 mg/kg limit and itself invokes a copper-alloy exemption; no broader conformity is inferred.
Request a current file match before relying on this record.
Standards as recorded: EN 60598-2-3:2003+A1:2011; EN IEC 60598-1:2021+A11:2022; EN 62493:2015 — considered satisfied without testing under clause 4.2.2; IEC 62031:2018 and EN IEC 62031:2020 — LED-module requirements in Attachment 1
Recorded conclusion: TR408-C identified as the tested sample; see assessment limits
TR408-C is the sample stated as fully tested; listed variants are not separately tested. The report considers EN 62493:2015 satisfied without testing under clause 4.2.2. No broader configuration or production conformity follows.
Request a current file match before relying on this record.
/quality-documents/#document-aoce250627899-s
AOCE250627899-SC — Voluntary conformity assessment certificate / attestation referencing a test report; 2025-07-01; Zhongshan AOCE Testing Technology Co., Ltd.
Standards as recorded: EN 60598-2-3:2003+A1:2011; EN IEC 60598-1:2021+A11:2022
Recorded conclusion: Sample-evaluation conclusion stated
Voluntary assessment of a sample and technical file, referencing AOCE250627899-S. This is not the manufacturer/importer declaration required before CE marking; confirm current requirements and the exact supplied configuration.
Request a current file match before relying on this record.
/quality-documents/#document-aoce250627899-sc
AZT250702002C-E0 — Test report; 2025-07-08; Shenzhen AZT Technology Co., Ltd.
Standards as recorded: RoHS Directive 2011/65/EU Annex II amended by Directive (EU) 2015/863; IEC 62321-3-1:2013; IEC 62321-5:2013; IEC 62321-4:2013+AMD1:2017 CSV; IEC 62321-6:2015; IEC 62321-7-1:2015; IEC 62321-7-2:2017; IEC 62321-8:2017
Recorded conclusion: Pass recorded; see report dependency
Submitted-sample and selected-material scope only. Parts 36/37 record lead at 17,748/28,372 mg/kg against a printed 1,000 mg/kg limit; the report invokes the copper-alloy exemption in Annex III 6(c). That exemption and its current applicability are not independently assessed here.
Request a current file match before relying on this record.
/quality-documents/#document-azt250702002c-e0
AZT250702002C-EV0 — Certificate of Conformity tied to a test report; 2025-07-08; Shenzhen AZT Technology Co., Ltd.
Standards as recorded: RoHS Directive 2011/65/EU Annex II amended by Directive (EU) 2015/863; IEC 62321-3-1:2013; IEC 62321-5:2013; IEC 62321-4:2013+AMD1:2017 CSV; IEC 62321-6:2015; IEC 62321-7-1:2015; IEC 62321-7-2:2017; IEC 62321-8:2017
Recorded conclusion: Submitted-sample conclusion stated
Selected-material and submitted-sample scope only; read with AZT250702002C-E0. Its conclusion depends on the report’s high-lead copper-alloy results and stated exemption, not independently assessed here.
Request a current file match before relying on this record.
Recorded conclusion: Pass recorded for the requested tests on the submitted sample components
Submitted-sample and selected-component scope only; the report says unlisted components were not tested and does not establish whole-production conformity.
Request a current file match before relying on this record.
Recorded conclusion: Pass recorded for the requested tests on the submitted sample components
Submitted-sample and selected-component scope only; the report says unlisted components were not tested and does not establish whole-production conformity.
Request a current file match before relying on this record.
Four checks take a record from this register into your tender or import file. One sample result does not cover every product or market.
Match the number
The document identifier, date, issuer and referenced report.
Match the model
Tested, listed, named and series models stay distinct.
Match the configuration
The current sample, drawing, rating label and bill of materials.
Match the destination
Current local requirements before qualification or shipment.
Request the documents for your model.
Send the product family, exact model if known, destination and document purpose. Some records include reviewed redacted page previews; metadata-only records do not. We match the records that name your model, and you can ask which complete file, if any, can be supplied for the exact model and purpose.